Skip to product information
1 of 3

SunPower

5 kW Solar System Kit — 10 × SunPower TCL 500W Panels + Dual 3,200W Hybrid Inverters + Mounting Rails

5 kW Solar System Kit — 10 × SunPower TCL 500W Panels + Dual 3,200W Hybrid Inverters + Mounting Rails

Regular price $4,139.99 AUD
Regular price $6,899.99 AUD Sale price $4,139.99 AUD
Sale Sold out
Shipping calculated at checkout.

This 5kW solar system kit combines ten 500W SunPower TCL panels, two 3,200W hybrid inverters and mounting rails for a 5,000W solar array. It is intended as the foundation for a professionally designed home, shed, cabin, commercial or off-grid project where the current inverter models, electrical design, battery requirements and mounting components are confirmed before ordering.

Important: the product title confirms the panel quantity, inverter capacities and mounting rails. Batteries, installation labour and unspecified balance-of-system components should not be assumed to be included. Ask StarPower for the current inverter model, panel datasheet, rail configuration and written packing list before purchase.

Confirmed 5kW Solar Kit Components

  • 10 × SunPower TCL 500W solar panels — 5,000W total nominal DC array capacity
  • 2 × 3,200W hybrid inverters — exact models and supported operating configuration must be confirmed
  • Mounting rails — rail lengths and roof-specific components must be checked against the installation

Cables, connectors, isolators, switchgear, batteries, roof attachments, clamps, earthing equipment and monitoring hardware are supplied only when expressly included in the current written packing list or quotation.

What a 5kW Solar System Can Suit

A 5kW solar array may suit medium household loads, workshops, sheds, cabins and selected independent-power systems. Suitability depends on daily energy use, simultaneous appliance loads, starting surges, roof orientation, shading, local solar conditions and—where off-grid operation is required—usable battery capacity and autonomy.

Prepare a load schedule before purchase. Record every appliance’s running watts, starting surge and expected hours of use. Off-grid designs should also account for seasonal production and consecutive low-sun days.

SunPower TCL 500W Panel Array

Array detail Confirmed value
Panel power 500W each
Panel quantity 10
Total nominal array 5,000W
Panel series SunPower TCL full-black panel as named in the listing

Panel dimensions, weight, voltage, current, warranty and approvals must be checked against the current supplied-panel datasheet. These details determine roof fit, lifting requirements, string configuration and inverter compatibility.

Compare the broader SunPower solar panel range and other 500W solar panels.

Dual-Inverter Design: Checks Required

The kit includes two inverters described as 3,200W hybrid units. Two inverter ratings should not automatically be treated as a single combined output. Confirm whether the exact models support parallel operation, how loads are divided, whether each inverter requires a separate PV string or battery connection, and what communications or synchronisation equipment is required.

  • Confirm maximum PV open-circuit voltage and MPPT operating range.
  • Confirm PV input-current limits for each proposed string.
  • Confirm battery voltage, supported chemistry and communications requirements.
  • Confirm continuous AC output, surge rating and parallel-operation capability.
  • Confirm single-phase or multi-phase configuration requirements.
  • Confirm current Australian approvals for the intended application.

Battery Storage Is a Separate Design Decision

A battery is not identified among the confirmed components above. Battery storage should be sized from overnight consumption, required backup time, depth-of-discharge limits, charging capacity and the inverter manufacturer’s compatibility list.

Browse lithium LiFePO4 batteries or AGM batteries, then have the complete battery system checked against both inverters before connection.

Expected Solar Production

The 5,000W array rating is measured under standard test conditions. Real production varies with location, season, panel angle and orientation, shade, temperature, soiling, cable losses and inverter operation. Obtain a site-specific estimate rather than relying on one national daily-output figure.

Mounting, Installation & Compliance

Confirm the roof type, rail lengths, panel layout, clamps, fixings, wind region, structural capacity and waterproofing requirements. Mounting rails alone do not necessarily constitute a complete mounting system.

Solar DC wiring, battery energy and 230/240V AC work can be hazardous. Fixed and grid-connected systems must be designed and installed by appropriately qualified professionals in accordance with applicable Australian requirements and manufacturer instructions. The term “hybrid inverter” does not by itself confirm grid-export approval.

Compare 3kW, 5kW & 10kW Solar Kits

Browse the broader off-grid solar kit range for other system sizes.

5kW Solar System FAQs

Does this kit include batteries?

Batteries are not listed among the confirmed product-title components. Do not assume battery storage is included unless it appears in the current written packing list or quotation.

Can the two inverters operate together?

That depends on the exact inverter model, firmware, communications equipment and approved wiring configuration. Confirm parallel-operation support before purchase.

Can this system be grid connected?

Grid connection depends on the exact inverter models, current approvals, network requirements and a compliant system design. Obtain qualified confirmation before ordering for a grid-connected project.

Is it suitable for off-grid use?

Potentially, when the inverters, battery bank, protection equipment and solar array are designed around the site’s loads and autonomy requirements.

Are all mounting and electrical parts included?

The title confirms mounting rails. Roof-specific fixings, clamps and electrical balance-of-system items must be confirmed against the current packing list.

Before Ordering

  • Request the current panel and inverter datasheets.
  • Confirm the full packing list and freight arrangements.
  • Provide the installation postcode, roof type and available roof dimensions.
  • Prepare an appliance load list and battery-runtime target.
  • Have a qualified installer verify string design, inverter configuration, mounting and compliance.
View full details
Loading customer reviews…